Total water hardness testing

Theory and Importance of Water Hardness Testing: Key Insights into Water Quality Analysis

Facebook
Twitter
LinkedIn
WhatsApp
Pinterest
Reddit

Table of Contents

Introduction to Water Hardness

Water hardness is primarily caused by the presence of dissolved minerals, particularly calcium (Ca²⁺) and magnesium (Mg²⁺) ions. These minerals are naturally found in water as it flows over or through soil and rocks. Hard water can lead to scaling in pipes, boilers, and other water-carrying systems, and it can also reduce the effectiveness of soaps and detergents.

Types of Hardness

  • Temporary Hardness
  • Permanent Hardness

Principle of Total Hardness Test

The total hardness test quantifies the total concentration of calcium and magnesium ions in the water. The test is typically performed using a titration method, where a known volume of water is titrated with a standard solution of a chelating agent, usually ethylenediaminetetraacetic acid (EDTA). The EDTA binds to the calcium and magnesium ions, forming stable, water-soluble complexes.

During the titration, a color indicator (such as Eriochrome Black T) is used, which changes color when all the calcium and magnesium ions have been bound by the EDTA. The amount of EDTA solution used to reach the endpoint is proportional to the hardness of the water.

Importance of Measuring Water Hardness

  • Industrial Applications:Prevents scaling in boilers and cooling towers.
  • Household Applications:Improves the efficiency of soaps and detergents.

Reasons for Adding Chemicals in the Test

01. EDTA (Ethylenediaminetetraacetic Acid)

By forming stable complexes with these ions, EDTA removes them from solution, allowing the total hardness to be quantified.

02. Buffer Solution (Usually Ammonia/Ammonium Chloride)

The binding of EDTA with calcium and magnesium ions is most effective at this pH level. Maintaining the correct pH ensures accurate and consistent results.

03. Eriochrome Black T (Indicator)

Eriochrome Black T binds weakly to calcium and magnesium ions, giving a wine-red color. When all the ions are complexed by EDTA, the indicator changes color (usually to blue), signaling the endpoint of the titration.

04. Deionized Water

It ensures that no additional ions are present that could interfere with the accuracy of the titration.

Temporary vs Permanent Water Hardness Explained

Temporary hardnessPermanent hardness
Caused byCalcium and magnesium hydrogencarbonates, Ca(HCO₃)₂ and Mg(HCO₃)₂Calcium and magnesium sulfates and chlorides, e.g. CaSO₄, MgCl₂
Removed by boiling?YesNo
Removed byBoiling, or adding lime (Ca(OH)₂)Ion exchange, washing soda (Na₂CO₃) or reverse osmosis

On boiling, hydrogencarbonates decompose and precipitate as scale:
Ca(HCO₃)₂(aq) → CaCO₃(s) + H₂O(l) + CO₂(g)
This is the white “fur” you see inside kettles. Total water hardness = temporary + permanent hardness.

How Water Hardness Is Expressed and Classified

Water hardness is usually reported as mg/L (ppm) of CaCO₃, even though magnesium contributes too – all Ca²⁺ and Mg²⁺ is expressed as the equivalent mass of calcium carbonate. Other units include German degrees (1 °dH = 17.8 mg/L CaCO₃).

Hardness (mg/L as CaCO₃)Classification
0 – 60Soft
61 – 120Moderately hard
121 – 180Hard
Above 180Very hard

Classification used by the U.S. Geological Survey.

Step-by-Step Procedure: EDTA Titration for Total Water Hardness

  1. Pipette 50.00 cm³ of the water sample into a clean conical flask.
  2. Add about 1–2 cm³ of ammonia/ammonium chloride buffer to bring the pH to about 10.
  3. Add 2–3 drops (or a small pinch) of Eriochrome Black T indicator. The solution turns wine-red.
  4. Fill a burette with standard 0.0100 mol dm⁻³ EDTA and record the initial reading.
  5. Titrate slowly with constant swirling. Near the end point the colour changes through purple – add EDTA drop by drop.
  6. Stop when the solution turns pure blue with no trace of red.
  7. Repeat to obtain concordant titres (within 0.10 cm³).

Calculating Total Water Hardness

EDTA reacts with Ca²⁺ and Mg²⁺ in a 1 : 1 ratio, so:

Total water hardness (mg/L as CaCO₃) = VEDTA × MEDTA × 100.09 × 1000 ÷ Vsample
(volumes in cm³, M in mol dm⁻³, 100.09 g mol⁻¹ = molar mass of CaCO₃)

Worked example

A 50.00 cm³ water sample needed a mean titre of 12.40 cm³ of 0.0100 mol dm⁻³ EDTA.

  1. Moles of EDTA = 0.0100 × (12.40 ÷ 1000) = 1.240 × 10⁻⁴ mol
  2. Moles of (Ca²⁺ + Mg²⁺) = 1.240 × 10⁻⁴ mol (1 : 1 ratio)
  3. Equivalent mass of CaCO₃ = 1.240 × 10⁻⁴ × 100.09 = 0.01241 g = 12.41 mg in 50.00 cm³
  4. Hardness = 12.41 mg ÷ 0.05000 L = 248 mg/L as CaCO₃ – very hard water

Measuring Calcium and Magnesium Hardness Separately

To find calcium hardness alone, raise the pH of a fresh sample to about 12–13 with sodium hydroxide. Magnesium precipitates as Mg(OH)₂ and no longer reacts, so titrating with EDTA (using an indicator such as murexide or calcon) measures only Ca²⁺.

Magnesium hardness = total hardness − calcium hardness

Common Mistakes and Tips

  • Wrong pH – without the pH 10 buffer, the EDTA complexes are less stable and the colour change is poor. Use fresh buffer, as ammonia evaporates over time.
  • Unclear end point – the change from purple to blue is gradual. Titrate slowly near the end point and compare against a flask that has just turned blue.
  • Interfering metal ions – iron, copper or aluminium can block the indicator. A masking agent such as triethanolamine can be added for such samples.
  • Using tap water for rinsing – always use deionised or distilled water, otherwise you add hardness to your sample.

Frequently Asked Questions

Why is the pH kept at 10 in a hardness titration?
At pH 10, EDTA forms stable complexes with both Ca²⁺ and Mg²⁺, and Eriochrome Black T shows a clear wine-red to blue colour change.

Why is water hardness expressed as CaCO₃?
It provides a single, standard unit so that water samples containing different mixtures of calcium and magnesium can be compared directly.

Is hard water harmful to health?
The World Health Organization has not set a health-based guideline value for water hardness. Its main problems are practical: scale in pipes, kettles and boilers, and poor lathering of soap.

Why does the colour change from wine-red to blue?
Eriochrome Black T is wine-red when bound to metal ions. EDTA binds the metals more strongly, so at the end point it removes them from the indicator, which returns to its free blue form.

Leave a Comment

Your email address will not be published. Required fields are marked *

Subscribe To Our Weekly Newsletter

Get notified about new articles

tute bucket logo2
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.